Product introduction:
Sy-cs-500 ultrasonic has many advantages in measuring the velocity of gas and fluid. Compared with the traditional mechanical flow meter and electromagnetic flow meter, it has the advantages of high measurement accuracy, strong adaptability to pipe diameter, non-contact fluid, convenient use, easy digital management, etc
Principle introduction:
The time difference method ultrasonic flowmeter is to use the time difference when the sound wave propagates the same distance along and against the flow in the fluid, and the difference of propagation time is related to the flow velocity of the measured fluid, so the difference of measurement time can be used to get the flow velocity of the fluid
Product composition:
1. Measure pipe section or field flue;
2. Transducer mounting base (with integrated purging device);
3. Ultrasonic transducer components and signal cables;
4. Flow meter converter;
5. Matching temperature and pressure transmitter (or optional sensor);
6. Supporting upper computer software.
Characteristic:
1. It is suitable for the measurement transformation of large-diameter flue gas, flare gas and industrial pipeline gas on site, with simple operation, convenient installation and maintenance; the minimum flow rate can be measured 0.3m/s, and the accuracy can reach 0.1m/s.
2. Single channel, double channel or multi-channel can be configured according to the user's requirements; with explosion-proof structure options, explosion-proof grade Exd Ⅱ BT6 and Exd Ⅱ CT6;
3. The measurement accuracy is high, up to 1.5 ~ 2.0;
4. Wide measuring range, up to 100:1;
5. Flexible nominal measurement, usually dn200-10000, can be customized with larger diameter;
6. It has small flow cutting function, high anti noise and strong reliability;
7. It can adapt to various gases and has complete signal output configuration.
Application Comparison of different types of flow meters
皮托管 | 热式流量计 | 超声流量计 | |
测量取样 | 点测量 | 点测量 | 全量程测量 |
计量精度 | 5%~10% | 5% | 1~2% |
流速限制 | 3m/s以上 | 0.3m/s~30m/s | |
颗粒物限制 | 易堵塞 | 无影响 | |
黏附物限制 | 易堵塞 | 影响很大 | 影响精度需吹扫 |
湿气限制 | 不能应用 | 影响精度小 | |
风向影响 | 影响大 | 影响大 | 几乎无影响 |
温度变化 | 影响大 | 无影响 |
Sy-cs-500 product technical index
Accuracy level: 1.5, 2.0;
Nominal diameter: dn200-dn10000, beyond the scope can be customized;
Working pressure: 0 ~ 1.6Mpa;
Working power supply: 24VDC
Ambient temperature: - 40-60 ℃;
Medium temperature: - 25-200 ℃;
Response time: < 1 s;
Input signal: temperature signal: 4-20mA; pressure signal: 4-20mA;
Output signal: 4-20mA DC, RS232 or RS485 and pulse signal;
Output load: 0 ~ 250 (4 ~ 20mA DC);
Power consumption: < 15 W;
Resolution: < 0.1 m/s;
Protection grade: IP65;
Explosion proof grade: ordinary non explosion proof, explosion-proof Exd Ⅱ BT6 and Exd Ⅱ CT6 are optional;
Self diagnosis function: it can self diagnose the operation status of each channel;
Data retention: no less than 3 years;
Display: on site LCD;
Probe material: 316L stainless steel bracket, titanium alloy transducer probe;
Dust removal device: design air back purging device